Pressure Ratings For Tubing and Threaded End Connections
Generally, tube fittings, adapters and components (fittings) are rated for pressures equal to the maximum allowable working pressures of the stainless tubing, hose or pipe recommended for use with the fittings. Pressure ratings for fittings with both tube fitting and stainless steel pipe thread ends are determined by the end connection with the lower pressure rating. Female and male pipe threads to have the same pressure rating in the same nominal pipe size. However to achieve the same pressure rating as the male pipe end, female ends require a heavier wall than practical.
Note that many specially designed fittings, bored-through fittings and fittings having AN, O-Seal and SAE/MS integral ends may have lower pressure ratings than that of the tubing. For more precise pressure ratings for a specific fitting, contact HT PIPE customer service.
What Is a Stainless Steel Pipe Pressure Rating?
A stainless steel pipe pressure rating describes the pressure a pipe or piping component is designed to withstand under defined conditions.
Depending on the source and application, a published value may refer to a calculated pressure limit, a manufacturer's working-pressure rating, or a rating for a complete component or connection.
These terms should not be used interchangeably.
Design pressure is the pressure basis used when designing a piping system. The design process must account for the applicable operating and abnormal conditions specified by the project.
Working pressure generally refers to the pressure at which equipment or a component is intended to operate under stated conditions. Its exact meaning depends on the manufacturer's documentation and applicable requirements.
Maximum allowable working pressure (MAWP) is a defined engineering limit for equipment or components under specified conditions. It should not be assumed to be identical to a generic pressure-chart value.
Burst pressure is the pressure at which a component fails during a particular test or under particular conditions. It is not an acceptable substitute for a design rating or safe working pressure.
For stainless steel pipe, the pressure rating must be considered together with the complete piping system. A pipe may have sufficient calculated pressure capacity while a flange, valve, gasket, threaded connection, welded joint, or fitting imposes a lower limit.
2. What Factors Affect Stainless Steel Pipe Pressure Ratings?
Material grade
The stainless steel grade influences the allowable stress used in pressure design. Common grades include 304, 304L, 316, and 316L, while duplex and high-alloy stainless steels may be selected for more demanding applications.
The allowable stress depends on the applicable design code, material specification, product form, and design temperature. Tensile strength alone cannot determine a pipe's allowable operating pressure.
A 316 stainless steel pipe and a 304 stainless steel pipe with identical dimensions should not automatically be assigned the same pressure rating. The appropriate values must be taken from the governing design rules for each material.
Outside diameter
Outside diameter affects the stress generated by internal pressure. For a given material, wall thickness, and design temperature, a larger diameter generally changes the pressure capacity and must be evaluated in the applicable design equation.
Nominal pipe size (NPS) is not the same as the measured outside diameter. Engineers should use the dimensional values specified by the applicable pipe standard and design method.
Wall thickness
Wall thickness is one of the most important factors in determining pressure capacity. With other conditions held constant, a thicker wall generally increases the pipe's ability to resist internal pressure.
However, the nominal wall thickness shown in a product specification may not equal the minimum actual wall thickness after manufacturing tolerances are considered. Corrosion allowance, erosion allowance, manufacturing tolerances, and other design requirements can reduce the wall thickness available for pressure resistance.
For this reason, pressure calculations should use the wall-thickness basis required by the applicable design code and purchase specification.
Design temperature
Stainless steel material properties change with temperature. At elevated temperatures, the allowable stress used for pressure design may decrease, reducing the permissible design pressure for the same pipe dimensions.
A pressure rating calculated at ambient temperature should therefore not be assumed to remain valid at an elevated operating temperature.
Low-temperature service also requires appropriate material and design review. Temperature limits, toughness requirements, and the properties of the complete piping system should be checked against the applicable specifications.
Manufacturing method and weld quality
Seamless and welded stainless steel pipes are manufactured differently. The applicable product specification and piping code determine how manufacturing quality, weld examination, and any relevant weld factors are addressed in design.
A welded pipe should not automatically be assigned an arbitrary pressure reduction factor. Any adjustment must come from the applicable standard, manufacturing specification, or documented engineering basis.
Buyers should confirm whether the requested product is seamless, welded, or otherwise manufactured and ensure that the quoted product meets the project requirements.
Connections and system components
A pipe's calculated pressure capacity does not necessarily establish the pressure rating of the entire piping assembly. Fittings, threaded ends, flanges, valves, seals, and mechanical joints may have different pressure limits.
The permissible operating conditions of the system are governed by the applicable design requirements and the limitations of the relevant components and connections.
3. Stainless Steel Pipe Pressure Rating Chart: How to Read the Data
Pressure charts can be useful for preliminary comparison, but the assumptions behind the numbers must be clear.
A stainless steel tube pressure chart may list outside diameter, wall thickness, and working pressure in pounds per square inch gauge (psig). Metric charts may list diameter in millimeters, wall thickness in millimeters, and pressure in bar.
Before using any chart, confirm the following:
- The material grade and product specification.
- Whether the dimensions refer to tubing or pipe.
- The outside diameter and wall thickness associated with each value.
- The reference temperature and allowable stress basis.
- Whether the values apply to seamless, welded, or drawn tubing.
- Whether the stated pressure is a manufacturer-rated working pressure or a calculated engineering value.
- Whether any connection, weld, temperature, or service limitations apply.
- A table developed for small-diameter instrumentation tubing should not automatically be used for large-diameter process piping. Likewise, pressure ratings for tube fittings or threaded connections cannot be applied to every pipe product.
Imperial stainless steel tubing pressure ratings
Imperial tubing charts commonly use fractional outside diameters, such as 1/4 inch, 3/8 inch, 1/2 inch, and 1 inch, together with wall thicknesses expressed in inches.
The pressure associated with each size and wall thickness must be read from a table whose material, temperature, manufacturing, and design assumptions are known.
If the original chart does not clearly state these assumptions, treat the values as preliminary reference information rather than approved design ratings.
Metric stainless steel tubing pressure ratings
Metric charts commonly list outside diameters such as 6 mm, 8 mm, 10 mm, 12 mm, and 20 mm. Wall thickness may be listed in increments such as 1.0 mm, 1.5 mm, 2.0 mm, or other specified dimensions.
The same interpretation rules apply to metric and imperial charts. A pressure value should only be used when the relevant product and design conditions match the basis of the chart.
Important note about pressure tables
A pressure chart is not a substitute for code-compliant design. If a table does not identify its material grade, design temperature, allowable stress basis, and product scope, its values should not be presented as universal maximum working pressures.
For critical services, confirm the design pressure with the responsible engineer and the applicable piping or pressure-equipment code.
4. How Pipe Schedule Affects Stainless Steel Pipe Pressure Ratings
Pipe schedule is a standardized way of identifying wall thickness for a given nominal pipe size. Common stainless steel schedules include Schedule 5S, 10S, 40S, and 80S.
For a given nominal pipe size, a heavier wall generally provides greater resistance to internal pressure, provided the material, temperature, design method, and other conditions remain comparable.
Schedule numbers do not represent a single wall thickness across all pipe diameters. The actual thickness associated with a schedule depends on the nominal pipe size and the applicable dimensional standard.
The letter "S" is used in stainless steel schedule designations under the relevant dimensional standards. Buyers should verify the actual specified wall thickness rather than relying on the schedule name alone.
For example, a project may specify 316L stainless steel pipe, NPS 2, Schedule 40S. That description identifies a material grade, nominal size, and schedule, but it is not enough on its own to establish a final pressure rating. The design temperature, allowable stress, applicable code, corrosion allowance, and other design conditions must also be considered.
When comparing Schedule 10S and Schedule 40S stainless steel pipe, confirm the actual wall thickness for the selected size. Do not assume the difference between two schedules produces the same pressure increase for every diameter or material.
5. How to Calculate Stainless Steel Pipe Pressure
Pressure design calculations must follow the governing code for the application. For process piping, ASME B31.3 is one commonly used code, while other systems may be governed by different piping or pressure-equipment requirements.
For straight pipe under internal pressure, a simplified form of the ASME B31.3 design equation is often presented as:
P = 2SEW t / (D - 2Yt)
where:
P = internal design pressure.
S = applicable material allowable stress at the design temperature.
E = applicable quality factor for the longitudinal weld joint, where relevant.
W = applicable weld joint strength reduction factor, where required.
t = pressure-design wall thickness available under the code.
D = outside diameter used by the design method.
Y = coefficient determined according to the applicable code and conditions.
This expression is a simplified reference form, not a universal formula for every pipe geometry, temperature, material condition, or design case. The exact equation, definitions, limits, allowances, and applicable factors must be verified against the current governing code.
The available wall thickness used in the calculation may need to account for corrosion, erosion, mechanical allowances, and applicable manufacturing tolerances. Additional requirements may apply to external pressure, cyclic service, high temperatures, branches, bends, and other nonstandard conditions.
Example: Why wall thickness alone is not enough
Suppose an engineer is comparing two stainless steel pipes with the same nominal size but different wall thicknesses.
The thicker-wall pipe will generally have a higher calculated internal-pressure capacity when all other design variables are held constant. However, a reliable pressure comparison still requires the correct material allowable stress, design temperature, weld factors where applicable, and the relevant wall-thickness allowances.
It would be misleading to assign a precise maximum working pressure using only the nominal diameter and schedule. A code-compliant calculation requires the full set of design inputs.
For a real project, the engineer should confirm the applicable standard and verify the final result before the piping system is approved for service.
Stainless Steel Tubing Pressure Ratings, Fractional Sizes
Notes: Shaded areas indicate tubing that is not suitable for gas service. For welded and drawn tubing, a derating factor must be utilized. For double welded tube, multiply the below pressure rating by 0.85; and for single welded tube by .80 (ANSI B 31, Table A-1B).
| Tube O.D.Size (Inches) | Wall Thickness of Tube (inches) | |||||||||||||||
| .010 | .012 | .014 | .016 | .020 | .028 | .035 | .049 | .065 | .083 | .095 | .109 | .120 | .134 | 0156 | .188 | |
| Working Pressure, psig | ||||||||||||||||
| 1/16 | 5600 | 6800 | 8100 | 9400 | 12100 | |||||||||||
| 1/8 | 8500 | 10900 | ||||||||||||||
| 3/16 | 5400 | 7000 | 10200 | |||||||||||||
| 1/4 | 4000 | 5100 | 7500 | 10200 | ||||||||||||
| 5/16 | 4000 | 5800 | 8000 | |||||||||||||
| 3/8 | 3300 | 4800 | 6500 | |||||||||||||
| 1/2 | 2600 | 3700 | 5100 | 6700 | ||||||||||||
| 5/8 | 2900 | 4000 | 5200 | 6000 | ||||||||||||
| 3/4 | 2400 | 3300 | 4200 | 4900 | 5800 | |||||||||||
| 7/8 | 2000 | 2800 | 3600 | 4200 | 4800 | |||||||||||
| 1 | 2400 | 3100 | 3600 | 4200 | 4700 | |||||||||||
| 1-1/4 | 2400 | 2800 | 3300 | 3600 | 4100 | 4900 | ||||||||||
| 1-1/2 | 2300 | 2700 | 3000 | 3400 | 4000 | 4900 | ||||||||||
| 2 | 2000 | 2200 | 2500 | 2900 | 3600 | |||||||||||
Stainless Steel Tubing Pressure Ratings - Metric Sizes
|
Tube OD |
Walll Thickness (mm) | |||||||||||||
| 0.8 | 1.0 | 1.2 | 1.5 | 1.8 | 2.0 | 2.2 | 2.5 | 2.8 | 3 | 3.5 | 4 | 4.5 | 5 | |
| Working Pressure (bar) | ||||||||||||||
| 3 | 670 | |||||||||||||
| 6 | 310 | 420 | 540 | 710 | ||||||||||
| 8 | 310 | 390 | 520 | |||||||||||
| 10 | 240 | 300 | 400 | 510 | 582 | |||||||||
| 12 | 200 | 250 | 330 | 410 | 470 | |||||||||
| 14 | 160 | 200 | 270 | 340 | 380 | 430 | ||||||||
| 15 | 150 | 190 | 250 | 310 | 360 | 400 | ||||||||
| 16 | 170 | 230 | 290 | 330 | 370 | 400 | ||||||||
| 18 | 150 | 200 | 260 | 290 | 320 | 370 | ||||||||
| 20 | 140 | 180 | 230 | 260 | 290 | 330 | 380 | |||||||
| 22 | 140 | 160 | 200 | 230 | 260 | 300 | 240 | |||||||
| 25 | 180 | 200 | 230 | 260 | 290 | 320 | ||||||||
| 28 | 180 | 200 | 230 | 260 | 280 | 330 | ||||||||
| 30 | 170 | 180 | 210 | 240 | 260 | 310 | ||||||||
| 32 | 160 | 170 | 200 | 220 | 240 | 290 | 330 | |||||||
| 38 | 140 | 160 | 190 | 200 | 270 | 270 | 310 | |||||||
| 50 | 150 | 210 | 210 | 240 | 270 | |||||||||